Production_Scaling_Plugin#
Classes:
|
Calculation of plant output and potential scaling. |
- class pyH2A.Plugins.Production_Scaling_Plugin.Production_Scaling_Plugin(dcf, print_info)[source]#
Calculation of plant output and potential scaling.
- Parameters
- Technical Operating Parameters and Specifications > Plant Design Capacity (kg of H2/day) > Valuefloat
Plant design capacity in kg of H2/day,
process_table()
is used.- Technical Operating Parameters and Specifications > Operating Capacity Factor (%) > Valuefloat
Operating capacity factor in %,
process_table()
is used.- Technical Operating Parameters and Specifications > Maximum Output at Gate > Valuefloat, optional
Maximum output at gate in (kg of H2)/day,
process_table()
is used. If this parameter is not specified it defaults to Plant Design Capacity (kg of H2/day).- Technical Operating Parameters and Specifications > New Plant Design Capacity (kg of H2/day) > Valuefloat, optional
New plant design capacity in kg of H2/day to calculate scaling, which overwrites possible Scaling Ratio,
process_table()
is used.- Technical Operating Parameters and Specifications > Scaling Ratio > Valuefloat, optional
Scaling ratio which is multiplied by current plant design capacity to obtain scaled plant size,
process_table
is used.- Technical Operating Parameters and Specifications > Capital Scaling Exponent > Valuefloat, optional
Exponent to calculate capital scaling factor,
process_table()
is used. Defaults to 0.78.- Technical Operating Parameters and Specifications > Labor Scaling Exponent > Valuefloat, optional
Exponent to calculcate labor scaling factor,
process_table()
is used. Defaults to 0.25.
- Returns
- Technical Operating Parameters and Specifications > Design Output per Day > Valuefloat
Design output in (kg of H2)/day.
- Technical Operating Parameters and Specifications > Max Gate Output per Day > Valuefloat
Maximum gate ouput in (kg of H2)/day.
- Technical Operating Parameters and Specifications > Output per Year > Valuefloat
Yearly output taking operating capacity factor into account, in (kg of H2)/year.
- Technical Operating Parameters and Specifications > Output per Year at Gate > Valuefloat
Actual yearly output at gate, in (kg of H2)/year.
- Technical Operating Parameters and Specifications > Scaling Ratio > Valuefloat or None
Returned if New Plant Design Capacity was specified.
- Scaling > Capital Scaling Factor > Valuefloat or None
Returned if scaling is active (Scaling Ratio or New Plant Design Capacity (kg of H2/day) specified).
- Scaling > Labor Scaling Factor > Valuefloat or None
Returned if scaling is active (Scaling Ratio or New Plant Design Capacity (kg of H2/day) specified).
Notes
To scale capital or labor costs, a path to Scaling > Capital Scaling Factor > Value or Scaling > Labor Scaling Factor > Value has to specified for the respective table entry.
Methods:
calculate_output
(dcf)Calculation of yearly output in kg and yearly output at gate in kg.
calculate_scaling
(dcf, print_info)Calculation of scaling if scaling is requested (either New Plant Design Capacity (kg of H2/day) or Scaling Ratio was provided).